參考價(jià)格
面議型號(hào)
品牌
產(chǎn)地
上海樣本
暫無(wú)看了3510型原子吸收分光光度計(jì)系統(tǒng)的用戶(hù)又看了
虛擬號(hào)將在 180 秒后失效
使用微信掃碼撥號(hào)
上海金鵬分析儀器有限公司綜合國(guó)內(nèi)外優(yōu)秀生化實(shí)驗(yàn)設(shè)備制造經(jīng)驗(yàn)**生產(chǎn)的3510型原子吸收分光光度計(jì)系統(tǒng),進(jìn)行系統(tǒng)詳解,可快速查詢(xún)產(chǎn)品的**報(bào)價(jià)、圖片、技術(shù)參數(shù),或者進(jìn)行產(chǎn)品性能比較,使用非常方便。
3510型原子吸收分光光度計(jì)系統(tǒng) u 經(jīng)濟(jì)的主機(jī)
u 高靈敏度高穩(wěn)定性的石墨爐系統(tǒng)
u 優(yōu)秀的光學(xué)系統(tǒng),確保測(cè)量數(shù)據(jù)準(zhǔn)確可靠
u 火焰法測(cè)試安全可靠
u 高效率的分析工作站
產(chǎn)品用途
3510主機(jī)具有內(nèi)置微機(jī)系統(tǒng),所有工作條件通過(guò)鍵盤(pán)設(shè)定,儀器能自動(dòng)尋找元素峰值能量,北京校正時(shí)空新陰極燈與氘燈的能量自動(dòng)平衡,并能處理數(shù)據(jù)和圖譜,真正體現(xiàn)了原子吸收分析系統(tǒng)快速、準(zhǔn)確、靈敏的特點(diǎn)
產(chǎn)品參數(shù)
波長(zhǎng)范圍:190.0nm-860.0nm
波長(zhǎng)準(zhǔn)確度:全波段≤±0.5nm
波長(zhǎng)重復(fù)性:≤ 0.3nm
閃耀波長(zhǎng):250nm
光譜帶寬:0.1nm.0.2nm,0.7nm,1.4nm(開(kāi)關(guān)選擇)
分辨率:光譜帶寬0.2nm,能分開(kāi)錳雙線(xiàn),即279.5nm和279.8nm,且二譜線(xiàn)間的峰谷能量值小于40%
讀書(shū)方式:連續(xù)、保持、峰高、峰面積
背景扣除:在背景信號(hào)為1ABS時(shí)具有30倍以上的背景扣除能力
吸光度范圍:0.000A-2.000A
穩(wěn)定性:在正常情況下,儀器和銅燈預(yù)熱半小時(shí)后,在不點(diǎn)火狀態(tài)下對(duì)銅譜線(xiàn)324.7nm測(cè)定基線(xiàn)穩(wěn)定性。30分鐘漂移量≤0.004吸光度
典型元素測(cè)定:火焰法,5mg/L的Cu吸光度大于0.800A
墨爐法靈敏度:Cu1×10-11g(特征量)
精密度:(相對(duì)標(biāo)準(zhǔn)偏差): ≤1%; ≤3%(Cu石墨爐測(cè)試)
特別申明:⑴本網(wǎng)站所列價(jià)目,如廠方有變動(dòng),請(qǐng)以廠家新價(jià)格為準(zhǔn)。
⑵批發(fā)優(yōu)惠幅度因各廠情況不同,請(qǐng)來(lái)電咨詢(xún)。
Analytical Instruments Co., Ltd. Shanghai Jinpeng excellent chemical and biological laboratory equipment and foreign manufacturing experience exclusively produced 3510 atomic absorption spectrophotometer system, for system Xiangjie to quickly check the latest products, quotes, pictures, technical parameters, or product performance comparison to use very convenient.
3510 atomic absorption spectrophotometer system, u host economy
u high sensitivity and high stability of the graphite furnace system
u good optical system to ensure accurate and reliable measurements
u safe and reliable Flame Test
u High-Efficiency Analysis Workstation
Usage
3510 mainframe with built-in microcomputer systems, all working conditions set by the keyboard, instruments can automatically search for elements of the peak energy, Beijing time correction new cathode lamp and deuterium lamp energy self-balancing, and can handle data and maps, and truly reflects the atomic absorption analysis system for fast, accurate and sensitive characteristics of
Product parameter
Wavelength range: 190.0nm-860.0nm
Wavelength Accuracy: full-band ≤ ± 0.5nm
Wavelength repeatability: ≤ 0.3nm
Blazed wavelength: 250nm
Spectral Bandwidth: 0.1nm.0.2nm, 0.7nm, 1.4nm (switch selection)
Resolution: spectral bandwidth of 0.2nm, manganese can be separated from two-lane, that is, 279.5nm and 279.8nm, and the two lines between the energy value of less than 40% of the peak and trough
Reading mode: Continuous, maintaining, peak height, peak area
Background subtraction: the background signal 1ABS more than 30 times when you have the ability to background deduction
Absorbance Range: 0.000A-2.000A
Stability: Under normal circumstances, the instruments and copper lamps warm half an hour later, without firing a state of the copper lines 324.7nm determine baseline stability. 30-minute drift ≤ 0.004 Absorbance
Determination of typical elements: Flame, 5mg / L of Cu absorption is greater than 0.800A
Mexican Furnace Sensitivity: Cu1 × 10-11g (characteristic amount)
Precision: (relative standard deviation): ≤ 1%; ≤ 3% (Cu graphite furnace testing)
In particular that: ⑴ prices listed on this site, such as a change in the factory, please factory new price shall prevail.
⑵ the wholesale margin of preference for each plant is different, please call us.
暫無(wú)數(shù)據(jù)!