EMP-5160是一臺(tái)用于電子顯微鏡樣品制備的自動(dòng)處理儀器.它是通過(guò)樣品在20個(gè)試劑瓶中連續(xù)順序地運(yùn)轉(zhuǎn),來(lái)完成樣品的固定、脫水及包埋, 整個(gè)樣品處理過(guò)程由微處理器精確控制。 樣品放置在各樣的樣品籃中,在電磁鐵和馬達(dá)驅(qū)動(dòng)裝置控制下,實(shí)現(xiàn)樣品籃從一個(gè)試劑瓶到另一個(gè)試劑瓶的移動(dòng)。試劑瓶的溫度、樣品浸泡時(shí)間等參數(shù)均可通過(guò)程序編制器便捷地設(shè)定. 該處理儀為用戶提供了可靠、靈活、大容量、自動(dòng)的樣品制備方案,廣泛應(yīng)用于生物、醫(yī)學(xué)等材料的光鏡和電鏡樣品制備。
The EMP 5160 is a productivity tool for the Electron Microscopy Laboratory. If you are embedding three or more times per week you cannot afford to process by hand. The EMP 5160 uses a proven robotics system to move baskets of tissue from one vial to another and agitates at the time and force you program, at the temperature you desire.
技術(shù)參數(shù):
Quality on Demand
Your laboratory can keep the same quality as manual processing but gain the time for other tasks and the convenience of doing things on a more predictable schedule. All tissues can be loaded and the timing set so that the tissue finishes at the time you desire. Each morning or afternoon the tissue is ready for you when you want it.
Safe, Versatile, Programming
The processor can come to you with your protocol loaded in internal memory. Your programs can be on external "data keys" that look like a large plastic key but have a memory chip inside, these can programmed by you or RMC. This is great for backup purposes, it is also a big relief if the primary operator is out and no-one is sure which protocol is loaded to run. By just putting the key into the unit and turning it the program is loaded, now just press Start. You can call this in from anywhere with confidence.
Operator Protection
This is the only system that uses Sealed Vials for all reagents. With any other carousel system the operator is potentially exposed to multiple hazardous vapors upon trying to inspect the process, change vials, retrieve the stack, etc. This can unnecessarily expose the operator and institution to risks. The EMP 5160 vials can be loaded in a hood, the instrument can be operated outside the hood and allows complete inspection of the system while operating, exchanging of vials, pulling the stack for adding samples, etc. without exposure to all reagents in the system.
Sample Handling Systems
The EMP 5160 uses traditional stack rings with stainless steel screen bottoms or the molded, one piece design with a center post. Both come with all the loading tools* necessary for easy and safe loading.
These two sample basket systems allow processing of up to 48 samples per run, running a few large samples up to 5mm x 5mm or extremely fine samples depending on your needs.
* The sample loading system has many features designed by Mr. Gregory Argentieri of Novartis, East Hanover, NJ. We thank him for his contribution to EM tissue processing.
主要特點(diǎn):
Microprocessor based with room for 50 protocols built into the instrument. These can be preprogrammed for you, sent to you on preprogrammed keys later or put into the unit or keys by the operator with the hand held programming unit.
Sealed Vials for operator safety, the vials can all be loaded in a hood and the EMP5160 operated in an open room. Transfer of the vials does not expose the operator to fumes as other units do.
Programming is done via detachable hand held keypad. When you have finished programming the programming unit is locked away to prevent tampering or accidental changing of a protocol.
Frugal! Can use just a couple of milliliters of fluid for one sample up to 18ml for a full load (up to 48 sample compartments).
Two proven sample handling systems, either the traditional snap rings with removeable screens or the multi-compartment baskets. Either type have all tools included.